當前位置:首 頁 ? News ? Company News ? How to calibrate electronic sphygmomanometer

How to calibrate electronic sphygmomanometer

文章來源:鑫志科技 / 作者:鑫志科技 / 發表時間:2021-10-19

The electronic sphygmomanometer, like the mercury sphygmomanometer, needs to be calibrated regularly. It is necessary to ensure calibration at least once a year to ensure the normal measurement data.

First, according to the standard operating instructions, the mercury sphygmomanometer without defects and the right upper arm can be respectively placed on the left upper arm, and the suspected accuracy of the electronic sphygmomanometer can be placed on the left upper arm. Naturally, the sphygmomanometer on both sides will stop inflation testing synchronously. After the blood pressure starts the electronic sphygmomanometer switch, stop the pressure measurement of the mercury sphygmomanometer immediately, measure continuously for 2 to 3 times, and take the uniform value, The uniform value of bilateral readings is the standard reading of two sphygmomanometer, and the mercury sphygmomanometer reading is the accurate blood pressure. The difference between the two standard readings is the bias of the electronic sphygmomanometer suspected of accuracy.

Second, first measure blood pressure with mercury column sphygmomanometer; After three minutes of rest, measure the blood pressure with an electronic sphygmomanometer for the second time; Then rest for three minutes, and measure the blood pressure for the third time with a mercury column sphygmomanometer; Take the uniform value of the first and third measurements. Compared with the value measured by the electronic sphygmomanometer for the second time, the difference should generally be less than 5 mm Hg. If it is not correct, then the electronic sphygmomanometer needs calibration. The most scientific calibration method is to take the electronic sphygmomanometer to the quality monitoring department for calibration once a year.

Factors affecting the accuracy of measurement results of electronic sphygmomanometer

1. The first generation of mechanical constant speed exhaust valves were often considered imprecise due to the use of rubber valves that were prone to aging; This technology has been eliminated by mainstream electronic sphygmomanometer manufacturers;

2. The software of electronic sphygmomanometer from different manufacturers is complete and different, and the stability and accuracy of measurement results are also far from each other;

3. Not calibrated or not calibrated regularly;

4. Improper application method: The correct application method is to adhere to the position of the cuff or wrist strap at the same level as the heart during the testing process, and also adhere to not speaking, sitting upright, and maintaining a stable mood;

5. Inappropriate use of people or places. Generally speaking, pay attention to the purchase of a good brand of electronic sphygmomanometer, and pay attention to the above points, then the measurement results of electronic sphygmomanometer still have some reference value.

咨詢

QQ

在線客服

服務時間:9:00-18:00

電話

服務咨詢熱線:

0755-2780-8770

微信

二維碼

微信咨詢

郵箱

電子郵箱

xuzb@xzkj.net.cn

主站蜘蛛池模板: 一级爱| 亚洲va精品中文字幕 | 日本99热| 国产高清免费视频 | 久久亚洲高清观看 | 国产精品久久久久尤物 | 欧美亚洲日本国产 | 婷婷夜夜躁天天躁人人躁 | 亚洲日本免费 | 久久久久久88色愉愉 | 日韩一区二区久久久久久 | 日本中文字幕在线观看 | 一线毛片 | 牛牛影院成人免费网页 | 精品爱爱| 五月天婷婷网址 | 男人都懂www深夜免费网站 | 91亚洲精品视频 | 自拍 欧美 在线 综合 另类 | 999精品视频在线 | 狠狠躁天天躁 | a级毛片毛片免费观看久潮 a级毛片免费 | 国产免费变态视频网址网站 | 激情五月综合网 | 国产精品嫩草影院奶水 | www.国产福利视频.com | 污视频在线网站 | ww毛片| 欧美一级aa免费毛片 | 久久伊人最新 | 日本三级做a全过程在线观看 | 奇米影视一区二区三区 | 日韩欧美在 | 99久久精品免费看国产免费 | 91精品国产综合久久欧美 | 成人淫片 | 日本黄色录象 | 四虎国产精品永久地址49 | 中文毛片 | 深夜在线网站 | 日本一片免费观看高清完整 |