Blood pressure/pulse discrimination method

文章來源:鑫志科技 / 作者:鑫志科技 / 發(fā)表時間:2021-08-27

Blood pressure/pulse discrimination method:

The criterion of systolic pressure is certain: when the ratio of the amplitude Ui of a pulse wave to the maximum amplitude Um Ui/Um=Ks in the rising segment of the pulse wave amplitude envelope during inflation, the corresponding cuff pressure at this time is considered as the systolic pressure. Ps=P Å Ui=Ks · Um. The diastolic pressure criterion is determined: when the ratio of the amplitude Ui of a pulse wave to the maximum amplitude Um Ui/Um=Kd in the descending section of the pulse wave amplitude envelope, the corresponding cuff pressure at this time is considered as diastolic pressure. Namely, Pd=P Å Ui=Kd · Um. Heart rate refers to the number of beats per minute of the heart. Due to the divergence between the heartbeat and pulse, it is possible to measure heart rate while measuring blood pressure. The key to measuring heart rate is to distinguish the peak value of pulse waves, and then calculate the heart rate based on how many pulse waves there are within a certain period of time.

Hardware circuit:

Pneumatic parts:

The pneumatic circuit consists of a cuff, an air pump, a pressure sensor, and a vent valve. The two signals output by the pressure sensor are filtered, amplified, and connected to the two A/D channels of the main controller to measure the static pressure signal and pulse signal; The air pump and vent valve are directly controlled by the main controller through the driving chip to complete the charging and discharging of the measurement time.

Pressure sensing local:

The characteristics of human physiological signals are low-frequency small signals, usually μ The V-mV level sensor has a frequency range of 0-300 Hz and a low signal-to-noise ratio. Therefore, it is very important to choose a sensor with good performance. In this plan, the US9111 sensor is selected to cooperate with two carefully designed filtering and amplification circuits to achieve high-quality signals.

Filter and amplify local:

The signal from the pressure sensor is a mixed signal of pulse signal and static pressure signal, mixed with high-frequency interference from the outside and DC or low-frequency weight. Static pressure signal belongs to low-frequency signal, with a frequency less than or equal to 0.04 Hz, and pulse signal frequency is generally about 1 Hz. Divide the mixed signal into two parts, one of which passes through a low-pass filtering circuit and is connected to an A/D converter to stop analog-to-digital conversion, obtaining static pressure signal data; The other path passes through another filtering and amplification circuit and stops analog-to-digital conversion to obtain amplified pulse signal data.

咨詢

QQ

在線客服

服務(wù)時間:9:00-18:00

電話

服務(wù)咨詢熱線:

0755-2780-8770

微信

二維碼

微信咨詢

郵箱

電子郵箱

[email protected]

主站蜘蛛池模板: 热久久这里是精品6免费观看 | 性欧美www | 99re热视频精品首页 | 国产精品成在线观看 | 呦女亚洲一区精品 | 五月中文字幕 | 看一级特黄a大片日本片黑人 | 久99久热 | 久久精品国产曰本波多野结衣 | 国产在线精品一区二区三区不卡 | 毛片免费毛片一级jjj毛片 | 日本大臿亚洲香蕉大片 | 天天射天天操天天 | 91久久亚洲国产成人精品性色 | 四虎影视久久久免费 | 一区二区三区在线观看免费 | 91精品久久| 毛片电 | 不卡国产视频 | 欧美亚洲国产精品久久高清 | 国产精品高清在线 | 四虎永久在线精品免费观看地址 | 婷婷综合五月中文字幕欧美 | 黄色自拍网站 | 亚洲高清日韩精品第一区 | 亚洲一级毛片免费看 | 亚洲综合资源 | 国产精品成人扳一级aa毛片 | 一区二区三区欧美在线 | 久久久久久九 | 一级毛片不收费 | 黄色免费看视频 | 亚洲精品第一区二区三区 | 色偷偷亚洲女人天堂观看欧 | 国内精品综合九九久久精品 | 日本成人一区 | 欧美v亚洲v国产v | 在线91精品亚洲网站精品成人 | 国产a精品 | 国产综合网站 | 91精品国产免费自在线观看 |