Blood pressure/pulse discrimination method

文章來源:鑫志科技 / 作者:鑫志科技 / 發表時間:2021-08-27

Blood pressure/pulse discrimination method:

The criterion of systolic pressure is certain: when the ratio of the amplitude Ui of a pulse wave to the maximum amplitude Um Ui/Um=Ks in the rising segment of the pulse wave amplitude envelope during inflation, the corresponding cuff pressure at this time is considered as the systolic pressure. Ps=P Å Ui=Ks · Um. The diastolic pressure criterion is determined: when the ratio of the amplitude Ui of a pulse wave to the maximum amplitude Um Ui/Um=Kd in the descending section of the pulse wave amplitude envelope, the corresponding cuff pressure at this time is considered as diastolic pressure. Namely, Pd=P Å Ui=Kd · Um. Heart rate refers to the number of beats per minute of the heart. Due to the divergence between the heartbeat and pulse, it is possible to measure heart rate while measuring blood pressure. The key to measuring heart rate is to distinguish the peak value of pulse waves, and then calculate the heart rate based on how many pulse waves there are within a certain period of time.

Hardware circuit:

Pneumatic parts:

The pneumatic circuit consists of a cuff, an air pump, a pressure sensor, and a vent valve. The two signals output by the pressure sensor are filtered, amplified, and connected to the two A/D channels of the main controller to measure the static pressure signal and pulse signal; The air pump and vent valve are directly controlled by the main controller through the driving chip to complete the charging and discharging of the measurement time.

Pressure sensing local:

The characteristics of human physiological signals are low-frequency small signals, usually μ The V-mV level sensor has a frequency range of 0-300 Hz and a low signal-to-noise ratio. Therefore, it is very important to choose a sensor with good performance. In this plan, the US9111 sensor is selected to cooperate with two carefully designed filtering and amplification circuits to achieve high-quality signals.

Filter and amplify local:

The signal from the pressure sensor is a mixed signal of pulse signal and static pressure signal, mixed with high-frequency interference from the outside and DC or low-frequency weight. Static pressure signal belongs to low-frequency signal, with a frequency less than or equal to 0.04 Hz, and pulse signal frequency is generally about 1 Hz. Divide the mixed signal into two parts, one of which passes through a low-pass filtering circuit and is connected to an A/D converter to stop analog-to-digital conversion, obtaining static pressure signal data; The other path passes through another filtering and amplification circuit and stops analog-to-digital conversion to obtain amplified pulse signal data.

咨詢

QQ

在線客服

服務時間:9:00-18:00

電話

服務咨詢熱線:

0755-2780-8770

微信

二維碼

微信咨詢

郵箱

電子郵箱

xuzb@xzkj.net.cn

主站蜘蛛池模板: 99精品热线在线观看免费视频 | 久草青青在线 | 99精品久久久久中文字幕 | 久久这里只有精品国产 | 国产综合欧美 | 国产精品亚洲片在线观看麻豆 | 思思久热re6这里有精品 | 青娱乐国产在线视频 | 国产主播福利在线 | 欧美亚洲图片 | 一级毛片老太婆交性欧美 | 夜夜嗷| 九九香蕉网 | 中国一级特黄高清免费的大片 | 国产大片91精品免费看3 | 成人毛片免费观看视频 | 正在播放一区 | 国产成人免费高清在线观看 | 欧美最猛的24k毛片视频 | 特级黄色毛片视频 | 国产精品19禁在线观看2021 | 久久久综合视频 | 欧美日韩中字 | 最新中文字幕在线 | 国产一级做a爱免费视频 | 久久成人亚洲 | 久久精品国产国产精品四凭 | 免费一级网站 | 国内欧美一区二区三区 | 日本不卡二区 | 久久久久久亚洲精品中文字幕 | 91中文字幕在线观看 | 伊人第一页 | 欧美一区a | 一本岛高清v不卡免费一三区 | 国产伦精品一区二区三区在线观看 | 欧美专区亚洲专区 | 成在线人免费视频一区二区三区 | 97视频在线播放 | 国内永久第一免费福利视频 | 国内精品日本久久久久影院 |