Measurement principle of sphygmomanometer scheme

文章來(lái)源:鑫志科技 / 作者:鑫志科技 / 發(fā)表時(shí)間:2021-08-27

Measurement principle of sphygmomanometer scheme:

The sphygmomanometer plans to measure the blood pressure using the oscillometric method, which is also called the pressure oscillation method.

Its working process is to inflate the cuff to block the arterial blood flow, and then detect the gas pressure in the cuff and extract the tiny pulse wave during the deflation process. As shown in the figure below, when the cuff pressure P is much higher than the systolic pressure, the pulse wave disappears, and as the cuff pressure decreases, the pulse begins to appear. When the cuff pressure increases from above the systolic pressure drop to below the systolic pressure Ps, the pulse wave will suddenly increase, reaching its maximum amplitude when uniformly pressing Pm. Then the pulse wave decays with the decrease in cuff pressure. Oscillographic blood pressure measurement is based on the relationship between pulse wave amplitude and cuff pressure to estimate blood pressure. The maximum value of the pulse wave corresponds to the uniform pressure Pm, and the systolic pressure Ps and diastolic pressure Pd are determined by the proportion of the corresponding maximum amplitude of the pulse wave.

When measuring blood pressure, as the pressure on the cuff decreases, the blood vessels change from blockage to conduction, which generates a series of small pulses in the cuff. Pick up the small pulse, connect its peak value into a curve, and get the envelope,. There are many detailed methods for using oscillography to determine systolic and diastolic blood pressure, which can be mainly summarized into two types: waveform characteristic method and amplitude coefficient method. The fundamental principle of the waveform feature method is to measure blood pressure by using the inflection point of the envelope of the pulse wave. The static pressure corresponding to the inflection point when rising is systolic pressure, and the static pressure corresponding to the inflection point when falling is diastolic pressure. This method has poor individual compliance and unstable measurement accuracy, and has gradually been replaced by the amplitude coefficient method.

The amplitude coefficient method is also known as the "normalization method". It is to normalize the amplitude of the pulse wave vibration signal compared to the maximum amplitude of the signal, and identify systolic and diastolic blood pressure by confirming the normalization coefficients of systolic and diastolic blood pressure, as shown in Figure 3. Among them, As is the amplitude of the pulse wave corresponding to systolic blood pressure, Am is the amplitude of the pulse wave corresponding to uniform blood pressure, Ad is the amplitude of the pulse wave corresponding to diastolic blood pressure, As/Am is the normalized value of systolic blood pressure Ps, Ad/Am is the normalized value of diastolic blood pressure Pd, Pc is the cuff pressure, and the horizontal axis represents the occasional decrease in pressure inside the cuff during the deflation process. As/Am=C1, Ad/Am=C2, corresponding to the positions of systolic and diastolic blood pressure, respectively. Based on the measured pulse amplitude and corresponding static pressure, systolic blood pressure Ps, diastolic blood pressure Pd, and mean blood pressure Pm can be obtained. The amplitude coefficient of normal systolic blood pressure is 0.46~0.64, and the amplitude coefficient of diastolic blood pressure is 0.43~0.73.

咨詢

QQ

在線客服

服務(wù)時(shí)間:9:00-18:00

電話

服務(wù)咨詢熱線:

0755-2780-8770

微信

二維碼

微信咨詢

郵箱

電子郵箱

xuzb@xzkj.net.cn

主站蜘蛛池模板: 四虎成人免费网站在线 | 亚洲视频99| 久久成人亚洲 | 国产手机在线视频放线视频 | 日本在线观看一级高清片 | 午夜成年人网站 | a级成人毛片久久 | 亚洲精品你懂的 | 亚洲欧美日韩国产综合专区 | 欧美一线视频 | 亚洲午夜网 | 国产免费一区二区三区在线 | 久草在线影视 | 欧美日韩91 | 日本一级毛片视频网站 | 成人a一级毛片免费看 | 国产精品久久久久久影院 | 亚洲乱码在线播放 | 一级不卡毛片免费 | 九色 91| 五月天色婷婷在线 | 九九热视频精品在线 | 四虎日韩 | 天天干天天操天天添 | 日韩在线视频一区 | 亚洲精品一区二区三区 | 青青久久精品国产免费看 | 日本精品视频在线观看 | 久久精品.com | 天天舔天天射 | 国产综合色香蕉精品五月婷 | 欧美三级午夜理伦三级小说 | 黄网站www| 四虎影视成人精品 | 午夜伦y4480影院中文字幕 | 欧美成人免费 | 国产图片综合区 | 日本亚洲免费 | 亚洲国产精品综合福利专区 | 亚洲悠悠色综合中文字幕 | 久久久久九九精品影院 |