Measurement principle of sphygmomanometer scheme

文章來源:鑫志科技 / 作者:鑫志科技 / 發表時間:2021-08-27

Measurement principle of sphygmomanometer scheme:

The sphygmomanometer plans to measure the blood pressure using the oscillometric method, which is also called the pressure oscillation method.

Its working process is to inflate the cuff to block the arterial blood flow, and then detect the gas pressure in the cuff and extract the tiny pulse wave during the deflation process. As shown in the figure below, when the cuff pressure P is much higher than the systolic pressure, the pulse wave disappears, and as the cuff pressure decreases, the pulse begins to appear. When the cuff pressure increases from above the systolic pressure drop to below the systolic pressure Ps, the pulse wave will suddenly increase, reaching its maximum amplitude when uniformly pressing Pm. Then the pulse wave decays with the decrease in cuff pressure. Oscillographic blood pressure measurement is based on the relationship between pulse wave amplitude and cuff pressure to estimate blood pressure. The maximum value of the pulse wave corresponds to the uniform pressure Pm, and the systolic pressure Ps and diastolic pressure Pd are determined by the proportion of the corresponding maximum amplitude of the pulse wave.

When measuring blood pressure, as the pressure on the cuff decreases, the blood vessels change from blockage to conduction, which generates a series of small pulses in the cuff. Pick up the small pulse, connect its peak value into a curve, and get the envelope,. There are many detailed methods for using oscillography to determine systolic and diastolic blood pressure, which can be mainly summarized into two types: waveform characteristic method and amplitude coefficient method. The fundamental principle of the waveform feature method is to measure blood pressure by using the inflection point of the envelope of the pulse wave. The static pressure corresponding to the inflection point when rising is systolic pressure, and the static pressure corresponding to the inflection point when falling is diastolic pressure. This method has poor individual compliance and unstable measurement accuracy, and has gradually been replaced by the amplitude coefficient method.

The amplitude coefficient method is also known as the "normalization method". It is to normalize the amplitude of the pulse wave vibration signal compared to the maximum amplitude of the signal, and identify systolic and diastolic blood pressure by confirming the normalization coefficients of systolic and diastolic blood pressure, as shown in Figure 3. Among them, As is the amplitude of the pulse wave corresponding to systolic blood pressure, Am is the amplitude of the pulse wave corresponding to uniform blood pressure, Ad is the amplitude of the pulse wave corresponding to diastolic blood pressure, As/Am is the normalized value of systolic blood pressure Ps, Ad/Am is the normalized value of diastolic blood pressure Pd, Pc is the cuff pressure, and the horizontal axis represents the occasional decrease in pressure inside the cuff during the deflation process. As/Am=C1, Ad/Am=C2, corresponding to the positions of systolic and diastolic blood pressure, respectively. Based on the measured pulse amplitude and corresponding static pressure, systolic blood pressure Ps, diastolic blood pressure Pd, and mean blood pressure Pm can be obtained. The amplitude coefficient of normal systolic blood pressure is 0.46~0.64, and the amplitude coefficient of diastolic blood pressure is 0.43~0.73.

咨詢

QQ

在線客服

服務時間:9:00-18:00

電話

服務咨詢熱線:

0755-2780-8770

微信

二維碼

微信咨詢

郵箱

電子郵箱

[email protected]

主站蜘蛛池模板: 午夜欧美精品久久久久久久久 | 亚洲精品区 | 狠狠干.com| 天天摸夜夜操 | 欧美一级h| 96精品国产高清在线看入口 | 黄 色 三 级 网站 | 久色精品 | 国产精品永久在线 | 今天的恋爱未删减在线观看 | 伊人色综合久久天天网 | 亚洲手机中文字幕 | 久久国产热视频 | 中文国产成人精品久久一 | 日日拍夜夜嗷嗷叫狠狠 | 97视频免费播放观看在线视频 | 国产丰满老厨女房乱 | 亚洲国产精品一区二区久久 | 国产成年人视频 | 国产欧美日韩精品a在线观看 | 福利在线网站 | 4htv影院永久免费在线地址 | 欧美成人小视频 | 日产国产精品久久久久久 | 哥也操| 欧美日韩国产58香蕉在线视频 | 欧美日本在线视频 | 一级特级欧美aa毛片免费 | 国产精品高清视亚洲一区二区 | 国产成人精品在线观看 | 毛片女人 | 欧美成人视 | 久久国产大片 | 日本色综合网 | 四虎黄色影视库 | 天堂日韩| 国产999视频 | 手机看片日韩国产 | 中文字幕在线免费播放 | 91久久亚洲精品国产一区二区 | 日韩高清一区二区 |